Attached files

file filename
EX-99.5 - EXHIBIT 99.5 - Applied UV, Inc.tm2024891d1_ex99-5.htm
EX-99.3 - EXHIBIT 99.3 - Applied UV, Inc.tm2024891d1_ex99-3.htm
EX-99.2 - EXHIBIT 99.2 - Applied UV, Inc.tm2024891d1_ex99-2.htm
EX-99.1 - EXHIBIT 99.1 - Applied UV, Inc.tm2024891d1_ex99-1.htm
EX-23.3 - EXHIBIT 23.3 - Applied UV, Inc.tm2024891d1_ex23-3.htm
EX-23.1 - EXHIBIT 23.1 - Applied UV, Inc.tm2024891d1_ex23-1.htm
EX-21.1 - EXHIBIT 21.1 - Applied UV, Inc.tm2024891d1_ex21-1.htm
EX-10.13 - EXHIBIT 10.13 - Applied UV, Inc.tm2024891d1_ex10-13.htm
EX-10.12 - EXHIBIT 10.12 - Applied UV, Inc.tm2024891d1_ex10-12.htm
EX-10.11 - EXHIBIT 10.11 - Applied UV, Inc.tm2024891d1_ex10-11.htm
EX-10.10 - EXHIBIT 10.10 - Applied UV, Inc.tm2024891d1_ex10-10.htm
EX-10.9 - EXHIBIT 10.9 - Applied UV, Inc.tm2024891d1_ex10-9.htm
EX-10.8 - EXHIBIT 10.8 - Applied UV, Inc.tm2024891d1_ex10-8.htm
EX-10.7 - EXHIBIT 10.7 - Applied UV, Inc.tm2024891d1_ex10-7.htm
EX-10.6 - EXHIBIT 10.6 - Applied UV, Inc.tm2024891d1_ex10-6.htm
EX-10.5 - EXHIBIT 10.5 - Applied UV, Inc.tm2024891d1_ex10-5.htm
EX-10.4 - EXHIBIT 10.4 - Applied UV, Inc.tm2024891d1_ex10-4.htm
EX-10.3 - EXHIBIT 10.3 - Applied UV, Inc.tm2024891d1_ex10-3.htm
EX-10.2 - EXHIBIT 10.2 - Applied UV, Inc.tm2024891d1_ex10-2.htm
EX-10.1 - EXHIBIT 10.1 - Applied UV, Inc.tm2024891d1_ex10-1.htm
EX-3.7 - EXHIBIT 3.7 - Applied UV, Inc.tm2024891d1_ex3-7.htm
EX-3.6 - EXHIBIT 3.6 - Applied UV, Inc.tm2024891d1_ex3-6.htm
EX-3.5 - EXHIBIT 3.5 - Applied UV, Inc.tm2024891d1_ex3-5.htm
EX-3.4 - EXHIBIT 3.4 - Applied UV, Inc.tm2024891d1_ex3-4.htm
EX-3.3 - EXHIBIT 3.3 - Applied UV, Inc.tm2024891d1_ex3-3.htm
EX-3.2 - EXHIBIT 3.2 - Applied UV, Inc.tm2024891d1_ex3-2.htm
EX-3.1 - EXHIBIT 3.1 - Applied UV, Inc.tm2024891d1_ex3-1.htm
S-1 - FORM S-1 - Applied UV, Inc.tm2024891d1_s1.htm

Exhibit 99.4

 

 

June 8, 2020

 

To:Max Munn

SteriLumen

50 N. Macquesten Parkway

Mount Vernon, NY 10550

 

From:Matthew Hardwick, PhD

ResInnova Laboratories

8807 Colesville Rd, 3rd Floor

Silver Spring, MD 20910

 

 

Dear Mr. Munn,

 

The Sterilumen mirror and drain units are estimated to have sufficient ultraviolet light (UV) intensity for a significant virus kill. Over the course of 2 hours, it is estimated that the mirror unit has a fluence of approximately 300 mJ/cm2. The drain unit has an estimated fluence of 36 mJ/cm2 after a 15 min exposure. Enveloped viruses, such as human coronavirus SARS CoV-2 (the virus that causes COVID19) and H1N1 influenza A, require approximately 4 mJ/cm2 for > 4-log kill1. It is anticipated that both units generate enough UV fluence in order to kill human coronaviruses.

 

Our laboratory tested both the mirror and drain units against H1N1 human influenza A virus. The units demonstrated a greater than 2.91-log (mirror) and a 4.21-log (drain) kill after 2 hours and 15 min, respectively. Please find the corresponding report in the following pages.

 

Testing against human coronavirus 229E, another enveloped RNA virus and a common surrogate for SARS CoV-2, has begun and results are anticipated in the next few weeks.

 

Sincerely,

 

/s/ Matthew Hardwick

 

Matthew Hardwick, PhD

President/CEO

ResInnova Laboratories

 

 

1Darnell, et al. Journal of Virological Methods (2004) 121:85-91

 

 

 

 

2

June 8, 2020

 

Antiviral Evaluation

 

Test Method Details

Test Method Modified ISO 18184
Test Organism H1N1 human influenza A virus
Test Solution Eagles Modified Medium with 2% Fetal Bovine Serum
Test Disks 20mm diameter magnetic stainless steel disk
Inoculum Applied to Test Disk 0.010 mL applied to each disk and spread to within 1mm of edges, then dried at room temperature
Recovery Solution Modified SDLP Buffer
Measuring Method of Number of Viable Viral Particles Dilution Plate Method onto MDCK cells, viral particles were detected by. Presence of viral particles (foci) were determined using an anti-XXX monoclonal antibody. Foci were then counted giving Foci Forming Units (FFU).

 

Results

Modified ASTM E2197: Standard Quantitative Disk Carrier Test Method
Number of Replicate Experiments 1
Average Concentration of Inoculum (FFU/mL) 3.55E+04 = 4.55 log
Average Control Recovery (FFU/mL) 3.72E+04 = 4.56 log

 

Location Average Virus
Recovered (FFU/disk)
Average
Log Recovery
Average
Log Reduction (vs
Control)
Average Percent
Reduction (vs
Control)
Sink Backsplash 5 0.70 4.06 >99.99%
Sink Edge 72.5 1.86 2.91 99.81%
Sink Drain 135 2.13 3.00 99.90%
Drain Pipe 1 2.5 0.40 4.21 >99.99%